HB-101 Hemoglobin Meter — Specifications

About this specification page
This page reproduces the HB-101 hemoglobin meter specification table exactly as listed on the company's website. HB-101 is one of only two models on this site with a specification table whose page title and body agree on the company's website, which is why it has a dedicated specification page. The table below is a transcription of the listed specification items; wording and values are kept as listed, including the original column heading that appears to be mislabelled.
The highlights listed on the company's HB-101 detail page are also recorded here: 1000 test memories, a small blood sample size, a large LCD, automatic switch-off, a deluxe carry case, and a four-step operating procedure, with automatic switch-off three minutes after the last operation to save power.
A figure recorded in parallel, not resolved
Two different result-time figures appear in the company's HB-101 material and are shown here side by side rather than resolved into one. The highlights on the company's detail page state a result in 15 seconds. A specification column lists a figure of under 10 seconds under a heading that appears to be mislabelled as a measurement range. This site does not choose one figure over the other and does not use either figure alone as a selling claim. A buyer who needs a single confirmed result-time figure should ask for it to be confirmed in writing.
Reference ranges and ordering notes
Hemoglobin reference ranges published on the company's category page are given as general information: men 130–170 g/L, women 120–150 g/L, infants 140–220 g/L, children 110–140 g/L, with samples of fingertip capillary and venous whole blood. Those ranges are general information only and do not replace professional medical guidance.
The HB-101 strip type is HS-101 and the quality control solution type is HC-101, as listed. Before payment, confirm strip supply, packing, pricing and current availability in writing. The company FAQ states that international orders are subject to an ongoing minimum order requirement with no fixed figure published, that samples take about 7 days, and that mass production takes 20–30 days after deposit. Certificates are available upon request. HB-201 and HB-202 must not be assumed to share this specification; no specification table for those models is published on this site.
| Item | Specification (as listed) |
|---|---|
| Sample | Capillary and Venous whole blood |
| Memory | 1000 tests |
| Sample Size | 10uL |
| Battery | 2xAAA Batteries |
| Test Strip Type | HS-101 |
| Battery lifetime | 1000 tests |
| Measuring Range | 4.5-25.6g/dL, 45-256g/L, 2.8-15.9mmol/L |
| Unit of measure | g/dL, g/L or mmol/L |
| Measurement Range (column heading as listed; value appears to relate to measurement time) | <10seconds |
| Dimensions | 126*57*24 mm |
| Operating Temperature | 10 – 40 ℃ (50℉- 104℉) |
| Operating Temperature Humidity | <90% |
| Meter Storage Temperature | -20℃ - 55℃ ( -4℉- 131℉) |
| Meter Storage Temperature Humidity | <90% |
| Strip Operating Temperature | 15-30℃ (59 ℉ ~ 86℉) |
| Strip Type | HS 101 |
| Strip Storage Temperature | 2-30℃ (35.6℉-86℉) |
| Quality Control Solution Type | HC-101 |
| Data Transmission Interface | PC |
| Weight | 185g (with battery) |
Reading the specification table
The specification table on this page is a transcription of the company's listed specification items for HB-101. Each row keeps the listed item name and value, including the original spelling and units. Two rows deserve a buyer's attention. The table lists ‘HS-101’ under ‘Test Strip Type’ and ‘HS 101’ under ‘Strip Type’. Both entries are retained as listed. Confirm whether they identify the same strip before ordering. Second, one column heading appears to be mislabelled: a row headed as a measurement range carries a value of under 10 seconds, which reads as a time figure rather than a range, and the frozen-parallel note on this page explains how that figure relates to the 15-second highlight.
Operating and storage conditions in the table cover the meter, the strips and the storage environment separately, with different temperature and humidity ranges for each. A buyer should read those rows as a set rather than picking one temperature figure, because meter, strip and storage conditions differ.
What the table does not cover
The table does not cover pricing, packing, strip supply quantities, instruction languages or current availability, because none of those items is part of the listed specification. Request written answers to those commercial questions for the specific order. The table also does not cover HB-201 or HB-202 in any way; those models have no specification table on this site, and no row here may be transferred to them.
Reference ranges published on the company's category page are general information about hemoglobin levels in different groups, not part of this specification. They are included on the hemoglobin meters category page for context and are not repeated as specification rows here.